Tools of the trade: Unimed External Sidestream ETCO2 Sensor

0
81

Estimated reading time: 2 minutes

 capnograph

by Jenna Collins VN, Wild Spirit Veterinary Clinic, St Helens, TAS

This capnograph is part of our monitoring system when patients are under anaesthesia or in an emergency situation where they require ventilation. It accurately measures CO2 in their exhaled breath.

What’s good about it

It provides a lot of information quickly, everything from whether there’s an obstruction to if the endotracheal tube is placed correctly to the depth of an anaesthesia. During an emergency situation, it’s often the first indicator that something is going wrong. If an animal is going into cardiac arrest, the capnograph will read a sudden drop in CO2. It also measures inspired carbon dioxide.

When attached to our Bionet Brio X5Vet monitor, the screen displays a continuous wave pattern with four different phases. Each of the waves has a specific shape that allows us to interpret how well the animal is doing. I’ve just completed a course through Practical Anaesthesia (practicalanaesthesia.com.au) that was very helpful. The trainer came to our practice and showed us how to use the capnograph and other instruments correctly.

Our practice opened in February so we’ve only been using the unit for the past few months. We’ve been getting steadily busier and using the capnograph—along with all our other equipment—more frequently. In that time, I’ve found it to be a reliable monitoring tool. 

What’s not so good

There can be some errors when undertaking a dental. When there’s a lot of fluid and condensation, the results can be inaccurate. That’s the time to draw on your experience as a nurse to read the situation correctly.

Where is it available

Mediquip

Previous articleTools of the trade: VetScalpel Laser VS-4025
Next articleTools of the trade: Oesophageal stethoscope

LEAVE A REPLY

Please enter your comment!
Please enter your name here